Reference testing standard: IEST-RP-CCO21.3
Test object: filter material
Test item: Filter material filtration efficiency, resistance
Test accuracy range: Filtration efficiency range: 20% -99.9995% Test air volume:
30L/min360L/min
Particle counter model: PMS Lasair ? Ⅲ110
Reference testing standard: EN18822-4
Test object: filter, filter material
Test item: Check if the filter leaks
Reference testing standard: IEST-RP-CCOO7.2, ANSI/ASHRAE 52.2
Test objects: air purifier filter, vacuum cleaner filter
Test items: Filter filtration efficiency, initial resistance
Testing accuracy range: Filtering efficiency range: 20% -99.99% (0.1-1.0 μ m)
Test air volume: 5m3/h~42m3/h
Particle counter model: TOPAS LAP 340/TSI 3330
Reference testing standard: IEST-RP-CCOO7.2
Test objects: air purifier filter, vacuum cleaner filter
Test items: Filter filtration efficiency, initial resistance
Testing accuracy range: Filtering efficiency range: 20% -99.9995% (0.1-1.0 μ m)
Test air volume: 10m3/h~200 m3/h
Particle counter model: PMS Lasair ? Ⅲ110
Reference testing standard: GB18801-2022 IEST-RP-CCOO7.2、ASHRAE52.2
Test objects: air purifier and its filter, fresh air fan filter
Test items: Initial filtration efficiency, initial resistance, and related PQ curve diagram Test
principle: Test and evaluate the initial efficiency, resistance, and other performance of an air
purifier or air filter at rated air volume
Test accuracy range: Filtration efficiency range: 20% -99.9995% (0.1-1.0 μ m) Test air volume:
100m3/h~2000 m3/h
Particle counter model: PMS Lasair ? Ⅲ110
Reference standards: GB/T 18801-2022 ANSI/AHAM AC-1-2020
Test object: Air purifier and fresh air fan
Test item: (PM2.5, PM1.0) particulate matter clean air volume
Test chamber volume: 30m 3
Equipment configuration: Laser aerosol particle size spectrometer (TSI3340), fully automatic
cigarette smoke generator
Reference standard: GB/T 18801-2022, GB/T 18204.2-2014
Test object: Air purifier and fresh air fan
Test item: Formaldehyde clean air volume
Test chamber volume: 30m 3
Equipment configuration: Air sampler, thermal desorption instrument, gas chromatograph TD-30/GC-2010
Pro
Reference standard: GB/T 18801-2022, GB/T 18204.2-2014
Test object: Air purifier and fresh air fan
Test items: particulate matter, formaldehyde, VOC clean air volume
Test chamber volume: 81m 3
Equipment configuration: Laser aerosol particle size spectrometer (TSI3340), fully automatic
cigarette smoke generator
Reference standard: GB/T 18801-2022, GB/T 18883-2022
Test object: Air purifier and fresh air fan
Test item: Gaseous pollutants (toluene, TVOC) Clean air volume
Test chamber volume: 30m 3
Equipment configuration: Air sampler, thermal desorption instrument, gas chromatograph TD-30/GC-2010
Pro
Reference testing standard: GB/T 18801-2022
Test objects: air purifier, fresh air fan
Test items: Cumulative purification of particulate matter, cumulative purification of gaseous
pollutants (formaldehyde, toluene, TVOC)
Test chamber volume: 3m 3
Equipment configuration: fully automatic cigarette smoke generator, fuel injection pump
Reference testing standard: UL867
Test objects: air purifier, fresh air fan
Test items: 24-hour ozone production, one-time ozone filtration efficiency, ozone lifespan
Test chamber volume: 30m 3
Equipment configuration: Ozone detector (MODEL-T400)
Reference standards: ANSI/ASHRAE 52.2 ISO/TS 11155-1
Test object: Vacuum cleaner filter, dust bag
Test items: dust holding capacity, resistance
Testing principle: By loading dust into the filter or dust collection bag, the final resistance is
tested according to the set loading amount and time to determine the dust holding capacity of the
filter or dust collection bag
Reference standard: EN779, ANSI/ASHRAE 52.2、ISO/TS 11155-1
Test object: Vacuum cleaner filter, dust bag
Test items: dust holding capacity, resistance
Testing principle: By loading dust into the filter or dust collection bag, the final resistance is
tested according to the set loading amount and time to determine the dust holding capacity of the
filter or dust collection bag
Reference standard: HJ 586-2010 Determination of free chlorine and total chlorine in water
quality
Test object: Water purification filter
Test item: residual chlorine, total hardness
Testing principle: Residual chlorine: Free chlorine reacts directly with N,
N-diethyl-1,4-phenylenediamine (DPD) to produce a red compound, and its absorbance is measured by
spectrophotometry. Total hardness: Calcium and magnesium ions in the water sample form a purple red
chelate with the chromium black T indicator. When pH=10, disodium ethylenediaminetetraacetic acid
first forms a chelate with calcium ions, and then with magnesium ions. When titrated to the
endpoint, the solution appears pure blue with the chromium black T indicator.
Reference standard: GB/T 30307-2013 Household and Similar Use Drinking Water Treatment Equipment
Test object: Household and similar drinking water treatment devices
Test items: hydrostatic pressure, rupture test, cyclic pressure
Testing principle: Conduct several impact experiments on the tested object by simulating the water
pressure in use to verify whether its structural strength can meet the usage requirements
Reference standard: GB/T 5750.4-2023 Standard Test Method for Drinking Water
Test object: Drinking water
Test items: Conductivity, pH
Testing principle: When the concentration of hydrogen ions changes, the electromotive force between
the glass electrode and the calomel electrode also changes. At 25 ℃, each unit of pH scale is
equivalent to a change in electromotive force of 59.1 mV, which is directly represented by the pH
reading on the instrument.
Reference standards: 1. GB/T 12496.8-2015 Test methods for wooden activated carbon Determination of
iodine adsorption value
2. GB/T 12496.5-1999 Test methods for wooden activated carbon
Determination of carbon tetrachloride adsorption rate (activity)
3. GB/T 7702.3-2008 Test Method for Granular Activated Carbon from Coal - Determination of Strength
Test object: Activated carbon
Test items: Iodine adsorption value, carbon tetrachloride adsorption capacity, strength
Testing of water filtration projects for the development of catalysts and chemical formulas corresponding to formaldehyde, ozone, and other VOCs: According to CNAS accreditation, water conductivity, pH value, hardness and other items can be tested and evaluated
Reference standards: GB/T 18801, GBT18883
Test object: Gaseous (volatile and semi volatile compounds)
Test items: TVOC, toluene, benzene
Reference standards: GB/T 18801, GBT18883
Test object: Formaldehyde
Testing principle: Quantitative analysis of sample substances using the visible spectral region
Reference standard: ISTA
Can the product structure of the simulated filter meet the requirements under extreme environmental
conditions of long-term storage and maritime transportation
Reference standards: UL94/UL900, EN, GB/T5169
Conduct combustion testing on the filter element and raw materials according to relevant standards
to evaluate whether they meet the corresponding flame retardant level requirements
Reference standards: GB2423.17, IEC60068-2-11
Conduct salt spray testing on the filter element and raw materials according to relevant standards
to evaluate whether they meet the corresponding corrosion resistance requirements
Reference standard: ISO2248 JISZ0202-87 GB/T4857.5
Test method: Full range drop of surface, angle, and edge
Drop height mm: adjustable from 300-1500
The maximum weight of the specimen is kg: 0-80kg
< br />
Falling height error: 1%
Reference standard: GB/T 4857.4 GB/T 4857.3
Measurement range ≤ 10KN
Distance between upper and lower pressure plates: 800mm
Measurement range: 800 * 800 * 800MM
Measurement accuracy: ≤± 1%
Compression speed: 0-85 mm/min (adjustable speed)
Reference standard: ISO 2247 ISO 13355 IEC 60068 ASTM D999 ASTM D4728 ASTM D3580 GB/T 4857 GB/T
2423
Frequency accuracy: 0.1Hz
Amplitude (mm) : 0-5
Vibration direction/waveform: triaxial (X+Y+Z)/sine wave
Test mode: fixed frequency, sweep frequency, double frequency, program, logarithm, random
Table size (mm) : (W) 800 x (D) 800 x (H) 720