每日更新国产av_浪货趴办公桌~H揉秘书电影无码_vr永久无码一区_国产亚洲视频在线播放不卡_美女被啪啪免费观看_一级香蕉视频_午夜电影院在线观看_久久精品碰国产一区_午夜无码中文字幕在线播放_日韩人妻精品黄色

About
Testing Capability
Committed to becoming your trusted filter manufacturer
Index/R&D/Testing Capability

Testing Capability

Filter

Filter material filtration efficiency and resistance
measuring table

Reference testing standard: IEST-RP-CCO21.3
Test object: filter material
Test item: Filter material filtration efficiency, resistance
Test accuracy range: Filtration efficiency range: 20% -99.9995% Test air volume: 30L/min360L/min
Particle counter model: PMS Lasair ? Ⅲ110

Filter leakage detection system

Reference testing standard: EN18822-4
Test object: filter, filter material
Test item: Check if the filter leaks

Filter efficiency and resistance
test bench (low air volume)

Reference testing standard: IEST-RP-CCOO7.2, ANSI/ASHRAE 52.2
Test objects: air purifier filter, vacuum cleaner filter
Test items: Filter filtration efficiency, initial resistance
Testing accuracy range: Filtering efficiency range: 20% -99.99% (0.1-1.0 μ m)
Test air volume: 5m3/h~42m3/h
Particle counter model: TOPAS LAP 340/TSI 3330

Filter efficiency and resistance
test bench (stroke volume)

Reference testing standard: IEST-RP-CCOO7.2
Test objects: air purifier filter, vacuum cleaner filter
Test items: Filter filtration efficiency, initial resistance
Testing accuracy range: Filtering efficiency range: 20% -99.9995% (0.1-1.0 μ m)
Test air volume: 10m3/h~200 m3/h
Particle counter model: PMS Lasair ? Ⅲ110

Filter efficiency and resistance measurement air duct

Reference testing standard: GB18801-2022 IEST-RP-CCOO7.2、ASHRAE52.2
Test objects: air purifier and its filter, fresh air fan filter
Test items: Initial filtration efficiency, initial resistance, and related PQ curve diagram Test principle: Test and evaluate the initial efficiency, resistance, and other performance of an air purifier or air filter at rated air volume Test accuracy range: Filtration efficiency range: 20% -99.9995% (0.1-1.0 μ m) Test air volume: 100m3/h~2000 m3/h
Particle counter model: PMS Lasair ? Ⅲ110

Detecting system

Purifier

Particle CADR measurement experimental chamber

Reference standards: GB/T 18801-2022 ANSI/AHAM AC-1-2020
Test object: Air purifier and fresh air fan
Test item: (PM2.5, PM1.0) particulate matter clean air volume
Test chamber volume: 30m 3
Equipment configuration: Laser aerosol particle size spectrometer (TSI3340), fully automatic cigarette smoke generator

Gaseous pollutant CADR measurement experimental chamber

Reference standard: GB/T 18801-2022, GB/T 18204.2-2014
Test object: Air purifier and fresh air fan
Test item: Formaldehyde clean air volume
Test chamber volume: 30m 3
Equipment configuration: Air sampler, thermal desorption instrument, gas chromatograph TD-30/GC-2010 Pro

81 cubic CADR measurement experimental chamber

Reference standard: GB/T 18801-2022, GB/T 18204.2-2014
Test object: Air purifier and fresh air fan
Test items: particulate matter, formaldehyde, VOC clean air volume
Test chamber volume: 81m 3
Equipment configuration: Laser aerosol particle size spectrometer (TSI3340), fully automatic cigarette smoke generator

VOC CADR
Measurement laboratory

Reference standard: GB/T 18801-2022, GB/T 18883-2022
Test object: Air purifier and fresh air fan
Test item: Gaseous pollutants (toluene, TVOC) Clean air volume
Test chamber volume: 30m 3
Equipment configuration: Air sampler, thermal desorption instrument, gas chromatograph TD-30/GC-2010 Pro

CCM experiment chamber for particulate matter
CCM experimental chamber for gaseous pollutants

Reference testing standard: GB/T 18801-2022
Test objects: air purifier, fresh air fan
Test items: Cumulative purification of particulate matter, cumulative purification of gaseous pollutants (formaldehyde, toluene, TVOC)
Test chamber volume: 3m 3
Equipment configuration: fully automatic cigarette smoke generator, fuel injection pump

Ozone testing
Experimental cabin

Reference testing standard: UL867
Test objects: air purifier, fresh air fan
Test items: 24-hour ozone production, one-time ozone filtration efficiency, ozone lifespan
Test chamber volume: 30m 3
Equipment configuration: Ozone detector (MODEL-T400)

Detection system

Vacuum cleaner/sweeping machine

Dust bag detection system -
Dust capacity/resistance

Reference standards: ANSI/ASHRAE 52.2 ISO/TS 11155-1
Test object: Vacuum cleaner filter, dust bag
Test items: dust holding capacity, resistance
Testing principle: By loading dust into the filter or dust collection bag, the final resistance is tested according to the set loading amount and time to determine the dust holding capacity of the filter or dust collection bag

Dust bag detection system -
filtration efficiency/resistance

Reference standard: EN779, ANSI/ASHRAE 52.2、ISO/TS 11155-1
Test object: Vacuum cleaner filter, dust bag
Test items: dust holding capacity, resistance
Testing principle: By loading dust into the filter or dust collection bag, the final resistance is tested according to the set loading amount and time to determine the dust holding capacity of the filter or dust collection bag

Detection system

Water purification filter element

Labeling - Life Test Bench - (Residual Chlorine/Hardness)

Reference standard: HJ 586-2010 Determination of free chlorine and total chlorine in water quality
Test object: Water purification filter
Test item: residual chlorine, total hardness
Testing principle: Residual chlorine: Free chlorine reacts directly with N, N-diethyl-1,4-phenylenediamine (DPD) to produce a red compound, and its absorbance is measured by spectrophotometry. Total hardness: Calcium and magnesium ions in the water sample form a purple red chelate with the chromium black T indicator. When pH=10, disodium ethylenediaminetetraacetic acid first forms a chelate with calcium ions, and then with magnesium ions. When titrated to the endpoint, the solution appears pure blue with the chromium black T indicator.

Water Hammer Laboratory Platform

Reference standard: GB/T 30307-2013 Household and Similar Use Drinking Water Treatment Equipment Test object: Household and similar drinking water treatment devices
Test items: hydrostatic pressure, rupture test, cyclic pressure
Testing principle: Conduct several impact experiments on the tested object by simulating the water pressure in use to verify whether its structural strength can meet the usage requirements

Conductivity/pH testing bench

Reference standard: GB/T 5750.4-2023 Standard Test Method for Drinking Water
Test object: Drinking water
Test items: Conductivity, pH
Testing principle: When the concentration of hydrogen ions changes, the electromotive force between the glass electrode and the calomel electrode also changes. At 25 ℃, each unit of pH scale is equivalent to a change in electromotive force of 59.1 mV, which is directly represented by the pH reading on the instrument.

Activated carbon performance testing (iodine value/ash content/hardness)

Reference standards: 1. GB/T 12496.8-2015 Test methods for wooden activated carbon Determination of iodine adsorption value
2. GB/T 12496.5-1999 Test methods for wooden activated carbon Determination of carbon tetrachloride adsorption rate (activity) 3. GB/T 7702.3-2008 Test Method for Granular Activated Carbon from Coal - Determination of Strength Test object: Activated carbon
Test items: Iodine adsorption value, carbon tetrachloride adsorption capacity, strength

Detection system

Chemical analysis

Multifunctional Chemistry
Analysis and Testing Laboratory

Testing of water filtration projects for the development of catalysts and chemical formulas corresponding to formaldehyde, ozone, and other VOCs: According to CNAS accreditation, water conductivity, pH value, hardness and other items can be tested and evaluated

Meteorological chromatography
Analyzer

Reference standards: GB/T 18801, GBT18883
Test object: Gaseous (volatile and semi volatile compounds)
Test items: TVOC, toluene, benzene

Spectrophotometer

Reference standards: GB/T 18801, GBT18883
Test object: Formaldehyde
Testing principle: Quantitative analysis of sample substances using the visible spectral region

Detection system

Product reliability

High temperature and high humidity experimental chamber
Cold and hot shock experimental chamber

Reference standard: ISTA
Can the product structure of the simulated filter meet the requirements under extreme environmental conditions of long-term storage and maritime transportation

Flame retardant testing chamber - European standard
Flame retardant testing chamber - American standard

Reference standards: UL94/UL900, EN, GB/T5169
Conduct combustion testing on the filter element and raw materials according to relevant standards to evaluate whether they meet the corresponding flame retardant level requirements

Salt spray test
Experimental cabin

Reference standards: GB2423.17, IEC60068-2-11
Conduct salt spray testing on the filter element and raw materials according to relevant standards to evaluate whether they meet the corresponding corrosion resistance requirements

Detection system

Packaging Material Verification Laboratory

Crane arm drop tester

Reference standard: ISO2248 JISZ0202-87 GB/T4857.5
Test method: Full range drop of surface, angle, and edge
Drop height mm: adjustable from 300-1500
The maximum weight of the specimen is kg: 0-80kg < br /> Falling height error: 1%

Paper box compression tester

Reference standard: GB/T 4857.4 GB/T 4857.3
Measurement range ≤ 10KN
Distance between upper and lower pressure plates: 800mm
Measurement range: 800 * 800 * 800MM
Measurement accuracy: ≤± 1%
Compression speed: 0-85 mm/min (adjustable speed)

Electromagnetic vibration test bench

Reference standard: ISO 2247 ISO 13355 IEC 60068 ASTM D999 ASTM D4728 ASTM D3580 GB/T 4857 GB/T 2423
Frequency accuracy: 0.1Hz
Amplitude (mm) : 0-5
Vibration direction/waveform: triaxial (X+Y+Z)/sine wave
Test mode: fixed frequency, sweep frequency, double frequency, program, logarithm, random
Table size (mm) : (W) 800 x (D) 800 x (H) 720